DESIGN AND CONSTRUCTION OF RADON 222 CONCENTRATION METER USING SEMICONDUCTOR TRANSDUCER

Show simple item record

dc.contributor.author HAMMED, TAOFEEK OLAJIDE
dc.date.accessioned 2021-06-29T11:50:00Z
dc.date.available 2021-06-29T11:50:00Z
dc.date.issued 2017-02
dc.identifier.citation M.Tech. en_US
dc.identifier.uri http://196.220.128.81:8080/xmlui/handle/123456789/3836
dc.description.abstract This thesis presents a method for monitoring radon concentration in air using a semiconductor photodiode as the transducer. A power supply unit, a simple ionization chamber, an analog system for signal discrimination and amplification, an embedded system based on arduino module microcontroller for measuring the transducer output and a Secured Digital (SD) Card Shield for logging measurement data were designed and constructed. The detection electrostatic chamber is made of a cylindrical aluminium tube with a copper rod running through the length of the tube and located at the tube axial centre. The body of the tube is the cathode while the copper wire is the anode. The Photodiode is fixed at the centre on the body of the tube and insulated from it. High Direct Current voltage of between 250 and 300V is applied to the chamber to ionize it. When radon decay, alpha particles are produced and accelerated to the cathode (the body of the chamber). The accelerated particles impinge on the semiconductor transducer fixed on the cathode and produces pulsation current whose peak is determined by the energy of the particle. The higher the number of energetic particles that are impinged on the transducer, the more the pulse current produced. The current pulse can then be counted and processed to give a measure of the concentration of the Radon. The developed system was tested and calibrated at Nigerian Institute of Radiation Protection (NIRP) Ibadan, Nigeria using Alpha 7401 Spectrometer available at the institute. The count per minute of the developed system has ±5% deviation with alpha 7401 spectrometer. The correlation value when the measurement of the two instruments was compared is 0.95. The total power consumption of the developed system is 1.5 watts. en_US
dc.description.sponsorship FUTA en_US
dc.language.iso en en_US
dc.publisher Federal University Of Technology, Akure. en_US
dc.subject DESIGN AND CONSTRUCTION OF RADON 222 en_US
dc.subject CONCENTRATION METER USING SEMICONDUCTOR TRANSDUCER en_US
dc.title DESIGN AND CONSTRUCTION OF RADON 222 CONCENTRATION METER USING SEMICONDUCTOR TRANSDUCER en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search FUTAspace


Advanced Search

Browse

My Account