DEVELPOMENT OF REFRIGERANTS RECOVERY AND RECYCLING MACHINE

Show simple item record

dc.contributor.author EICHE, JOHNSON FELIX
dc.date.accessioned 2021-07-19T10:25:39Z
dc.date.available 2021-07-19T10:25:39Z
dc.date.issued 2015-04
dc.identifier.uri http://196.220.128.81:8080/xmlui/handle/123456789/4245
dc.description.abstract In an attempt to reduce the rate of ozone-depletion and global warming effects, a refrigerant recovery/recycling machine was designed, fabricated and evaluated. The machine consists of a heat exchanger, capillary tubes, filter dryer, solenoid valves and 18 ℎ𝑝 (93.25 W) hermetically reciprocating compressor. The machine was tested using R12 and R22 refrigerants and the results of its performance tests indicated that the machine has 87.5 % recovery efficiency and 85.68 % recycling efficiency. The capacity of the machine is 19.44 kg/hr. All materials used for the construction were sourced locally, and the estimated cost of producing this machine is one hundred and six thousand, five hundred and eighty three naira (N106, 583.00). en_US
dc.description.sponsorship FUTA en_US
dc.language.iso en en_US
dc.publisher The federal university of technology,Akure. en_US
dc.subject refrigerant recovery/recycling machine en_US
dc.title DEVELPOMENT OF REFRIGERANTS RECOVERY AND RECYCLING MACHINE en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)