FACTORS AFFECTING COMFORT LEVEL OF BUILDINGS IN LAGOS STATE

Show simple item record

dc.contributor.author OLOKO, GANIYU ADEKUNLE.
dc.date.accessioned 2022-11-28T12:56:19Z
dc.date.available 2022-11-28T12:56:19Z
dc.date.issued 2004-10
dc.identifier.uri http://196.220.128.81:8080/xmlui/handle/123456789/5427
dc.description M.ENG THESIS en_US
dc.description.abstract The problem of natural cooling of buildings in tropical climate has been considered in this research. Two locations Ebute Metta of Lagos Mainland and Ikorodu zones were chosen for the research where the ambient and room (indoor) temperatures of some selected buildings were taken. The research showed that natural cooling of buildings could be achieved by: • Building houses/rooms to face South or North. • Using asbestos sheets as roofing Material • Leaving spaces between buildings to allow for free airflow. etc. • Limiting the number of people using a room. Statistical methods were used in the analysis of the collected data which later showed that the both calculated and measured data are almost equal in every aspect. en_US
dc.description.sponsorship FEDERAL UNIVERSITY OF TECHNOLOGY AKURE en_US
dc.language.iso en en_US
dc.publisher FEDERAL UNIVERSITY OF TECHNOLOGY AKURE en_US
dc.subject BUILDINGS en_US
dc.subject HOUSE DESIGN en_US
dc.title FACTORS AFFECTING COMFORT LEVEL OF BUILDINGS IN LAGOS STATE en_US
dc.type Thesis en_US